HT-504 room temperature COS hydrolysis catalyst
+
  • HT-504 room temperature COS hydrolysis catalyst

HT-504 room temperature COS hydrolysis catalyst

Category:Organic sulfur catalyst series

Used to hydrolyze COS in coal gas to H2S. It features a low activation temperature, good low-temperature activity, high conversion rate, and strong sulfur and oxygen resistance.

Product Details

I. Main Features and Applications

Used to hydrolyze COS in coal gas into H2S. It has the characteristics of low activation temperature, good low-temperature activity, high conversion rate, and strong sulfur and oxygen resistance.

 

II. Physical Properties and Technical Parameters

Item

Index

Appearance

White spherical

Specifications,mm

Ø(3~5)

Ø(5~7)

Bulk density,g/cm3

0.60~0.80

0.60~0.80

Strength,N/piece

≥50

≥60

COS conversion rate,%

≥99

Operating pressure,Mpa

≤8.0

Operating temperature,℃

50~150

Main components

Active components loaded on alumina

 

III. Process Operating Conditions

  Operating temperature: 50~150℃

  Operating pressure: ≤8.0Mpa

  Space velocity: 500~1500h-1